Pepro LLC

Pepro WALK-IN Sites

Walk-In Units are shielded against the effects of lightning, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI), and Electromagnetic Pulse (EMP) by employing our patented Faraday Cage Technology.

Pepro Remote Communication Shelter, Walk-In Shelter, Mountain-Top Shelter, Cell-on-Wheels (COWS), Site-on-Wheels (SOWS), Tower-on-Wheels (TOWS), Mobile Tower Unit (MTU)

24 ft x 24 ft Tower Base Communication Shelter

The shielding also lessens the effects of Passive Intermodulation (PIM) from outside sources. These units are offered in a variety of sizes that can provide a wide range of equipment configurations, which allow access to both the front and the back of the equipment after installation.

Pepro Remote Communication Shelter, Walk-In Shelter, Mountain-Top Shelter, Cell-on-Wheels (COWS), Site-on-Wheels (SOWS), Tower-on-Wheels (TOWS), Mobile Tower Unit (MTU)

16 ft x 16 ft Permanent Shelter with ice bridge platform


Specs/Sizes*
6×6
6×8
8×8
8×10
8×12
8×16
16×16 (2pc)
24×24 (2pc)
Weight (lbs)
2,400
2,500
2,950
3,200
4,500
7,000
7,000/pc
7,500/pc
Total Area
10×10
10×12
12×12
12×14
12×16
12×20
20×20
28×28
Leveling Jacks
4
4
4
4
6
6
Slab
Slab
Cable Entry Ports
9
9
9
9
9
9
18
18
Floor Load (lbs/sq. ft)
400
400
400
400
400
400
400
400
Roof Load (lbs/sq. ft)
200
200
200
200
200
200
200
200
7ft Racks
1
1
2
4
6
7
21
36
Max. Attached Tower Height
40'
40'
52'
52'
52'
52'
NA
NA

* Other configurations available

GroundingIncluded With Each Shelter
Pepro's Faraday Cage DesignCorner Lifting Lugs
Ufer Ground Cement Pads ProvidedInsulation and FRP Paneling
EGB Pass Thru at Power Entry LocationRubber Composite Floor